E8 CAME — Barrier Cabinet Door Open
At a glance
- Severity
- FAULT STOP
- Domain
- GATE_GARAGE_AUTOMATION
- Reference standard
- EN 12453 / EN 12445
What it means
The GLT40 board reports E8: the cabinet door unlock microswitch sees the door open. Either the door is not closed or the micro is faulty or disconnected.
Probable causes
- Cabinet door not closed or not latched
- Door microswitch faulty or misadjusted
- Microswitch wiring interrupted or oxidized