E1 CAME — Travel Calibration Error / Calibration Not Completed
At a glance
- Severity
- FAULT STOP
- Domain
- GATE_GARAGE_AUTOMATION
- Reference standard
- EN 12453 / EN 12445
- Product / context
- Calibration error
What it means
The control unit reports a calibration error: the travel self-learning was not completed or never run. On BXV it requires the correct A1 Motor type, the encoder enabled (F11) and a friction-free travel; then run A3 Travel calibration.
Probable causes
- A3 travel calibration never run after installation or board replacement
- A1 Motor type not matching the installed model
- Encoder disabled (F11 OFF): the A3 menu item does not appear
- Mechanical friction preventing the calibration from completing