E1 CAME — Limit Switch Fault / End of Travel Error
At a glance
- Severity
- WARNING
- Domain
- GATE_GARAGE_AUTOMATION
- Reference standard
- EN 12453 / EN 12445
What it means
The gate overruns the fully open or closed position, or stops in the wrong place: a moved or broken limit switch, a dirty encoder or a calibration never redone. After any work on limit switches or mechanics the travel must be re-learned.
Probable causes
- Mechanical limit switch displaced or broken
- Motor encoder faulty or dirty
- Control board not calibrated after installation
- Limit switch adjustment screw not calibrated
Full guided diagnosis in the app
The diagnostic tree for this fault has 3 guided steps with measurements, checks and resolutions. You'll find it in BASIQ, one of the five IndexOS apps: free, works offline.
Printable sheet + CAME updates
Leave your email: get the link to the printable CAME error-code sheet and a heads-up when we add new codes and guides.
Double opt-in, zero spam, one-click unsubscribe.
The same fault on other brands
More CAME codes
- E1 — Travel Calibration Error / Calibration Not Completed
- E10 — Obstruction Detected During Opening
- E11 — Consecutive Obstruction Limit Exceeded
- E12 — Line Voltage Absent
- E14 — Serial Communication Error (Board to Board)
- E16 — SLAVE Barrier Cabinet Door Open (Paired Mode)
- E17 — Wireless System Not Communicating
- E18 — Wireless System Not Configured