E17 CAME — Wireless System Not Communicating
At a glance
- Severity
- WARNING
- Domain
- GATE_GARAGE_AUTOMATION
- Reference standard
- EN 12453 / EN 12445
- Product / context
- Wireless system not communicating
What it means
The panel does not communicate with the wireless module: radio accessories (RIO edges, photocells) do not respond. Check the module seating and power with the supply off; if it stays silent after a new learning procedure, replace it.
Probable causes
- Wireless module not fully seated or not powered
- Wireless learning procedure to be repeated
- Wireless module failed
- Radio device with flat battery or out of range
Where to start
After checking, with power off, that the wireless module is seated and powered on the control panel, does the panel communicate with the module?