E13 CAME — Limit Switch Fault / End of Travel Error
At a glance
- Severity
- WARNING
- Domain
- GATE_GARAGE_AUTOMATION
- Reference standard
- EN 12453 / EN 12445
- Product / context
- Both limit switches are open
What it means
The gate overruns the fully open or closed position, or stops in the wrong place: a moved or broken limit switch, a dirty encoder or a calibration never redone. After any work on limit switches or mechanics the travel must be re-learned.
Probable causes
- Mechanical limit switch displaced or broken
- Motor encoder faulty or dirty
- Control board not calibrated after installation
- Limit switch adjustment screw not calibrated
Where to start
Does the gate go past the fully open or fully closed position?
Full guided diagnosis in the app
The diagnostic tree for this fault has 3 guided steps with measurements, checks and resolutions. You'll find it in BASIQ, one of the five IndexOS apps: free, works offline.
Printable sheet + CAME updates
Leave your email: get the link to the printable CAME error-code sheet and a heads-up when we add new codes and guides.
Double opt-in, zero spam, one-click unsubscribe.
The same fault on other brands
More CAME codes
- E1 — Travel Calibration Error / Calibration Not Completed
- E10 — Obstruction Detected During Opening
- E11 — Consecutive Obstruction Limit Exceeded
- E12 — Line Voltage Absent
- E14 — Serial Communication Error (Board to Board)
- E15 — Radio Interference / Remote Control Failure
- E16 — SLAVE Barrier Cabinet Door Open (Paired Mode)
- E17 — Wireless System Not Communicating