E14 CAME — Serial Communication Error (Board to Board)
At a glance
- Severity
- FAULT STOP
- Domain
- GATE_GARAGE_AUTOMATION
- Reference standard
- EN 12453 / EN 12445
- Product / context
- Serial communication error
What it means
Serial communication error between the two boards in paired operation: RSE card missing or not fully seated, cable not UTP CAT 5, or F49 Paired not set. Programming must be performed only on the MASTER board.
Probable causes
- RSE card missing or not fully seated on one of the two boards
- Connection cable not UTP CAT 5
- F49 Paired not set, or programming done on the SLAVE board
Where to start
On which type of installation does the error appear?
Full guided diagnosis in the app
The diagnostic tree for this fault has 7 guided steps with measurements, checks and resolutions. You'll find it in BASIQ, one of the five IndexOS apps: free, works offline.
Printable sheet + CAME updates
Leave your email: get the link to the printable CAME error-code sheet and a heads-up when we add new codes and guides.
Double opt-in, zero spam, one-click unsubscribe.
More CAME codes
- E1 — Travel Calibration Error / Calibration Not Completed
- E10 — Obstruction Detected During Opening
- E11 — Consecutive Obstruction Limit Exceeded
- E12 — Line Voltage Absent
- E13 — Limit Switch Fault / End of Travel Error
- E15 — Radio Interference / Remote Control Failure
- E16 — SLAVE Barrier Cabinet Door Open (Paired Mode)
- E17 — Wireless System Not Communicating