E16 CAME — SLAVE Barrier Cabinet Door Open (Paired Mode)
At a glance
- Severity
- FAULT STOP
- Domain
- GATE_GARAGE_AUTOMATION
- Reference standard
- EN 12453 / EN 12445
- Product / context
- SLAVE motor door open
What it means
In paired mode (MASTER/SLAVE via RSE) the MASTER board reports E16: the SLAVE barrier cabinet door unlock microswitch sees the door open.
Probable causes
- SLAVE barrier cabinet door not closed
- SLAVE door microswitch faulty or misadjusted
- Wiring between SLAVE micro and board interrupted
Where to start
Is the SLAVE barrier cabinet door fully closed (display shows [Sla])?
Full guided diagnosis in the app
The diagnostic tree for this fault has 3 guided steps with measurements, checks and resolutions. You'll find it in BASIQ, one of the five IndexOS apps: free, works offline.
Printable sheet + CAME updates
Leave your email: get the link to the printable CAME error-code sheet and a heads-up when we add new codes and guides.
Double opt-in, zero spam, one-click unsubscribe.
More CAME codes
- E1 — Travel Calibration Error / Calibration Not Completed
- E10 — Obstruction Detected During Opening
- E11 — Consecutive Obstruction Limit Exceeded
- E12 — Line Voltage Absent
- E13 — Limit Switch Fault / End of Travel Error
- E14 — Serial Communication Error (Board to Board)
- E15 — Radio Interference / Remote Control Failure
- E17 — Wireless System Not Communicating