Door left open Paxton — Door Timeout / Door Held Open
At a glance
- Severity
- WARNING THEN STOP
- Domain
- ACCESS_CONTROL
- Reference standard
- EN 60839-11 / CEI 79-18
- Product / context
- Door left open past programmed timeout
What it means
The door remains open beyond the maximum allowed time after an authorized access. The system reports a door held open alarm, which may indicate a mechanical problem, a user holding the door, or a door closer malfunction.
Probable causes
- Door closer poorly adjusted or faulty, does not close completely
- Door blocked open by a wedge or object
- Door status magnetic contact misaligned or faulty
- Door held open time configured too short in the controller
- Electric lock not releasing properly