ACU offline Paxton — Communication Lost / Controller Offline
At a glance
- Severity
- FAULT STOP
- Domain
- ACCESS_CONTROL
- Reference standard
- EN 60839-11 / CEI 79-18
- Product / context
- Access control unit offline
What it means
The access control controller is not communicating with the management server. Doors continue to operate in offline mode (if configured), but events are not logged on the server and configuration changes do not reach the controller.
Probable causes
- Ethernet cable disconnected or switch port faulty
- Controller IP address in conflict or incorrect network configuration
- Network switch faulty or unpowered
- Access management server unreachable or service stopped
- Firewall blocking the controller communication port
Where to start
Does the controller respond to ping from the server workstation?
Full guided diagnosis in the app
The diagnostic tree for this fault has 8 guided steps with measurements, checks and resolutions. You'll find it in BASIQ, one of the five IndexOS apps: free, works offline.
Printable sheet + Paxton updates
Leave your email: get the link to the printable Paxton error-code sheet and a heads-up when we add new codes and guides.
Double opt-in, zero spam, one-click unsubscribe.
The same fault on other brands
More Paxton codes
- Door forced — Door Forced Open
- Door left open — Door Timeout / Door Held Open
- Reader fault — Reader Offline / Reader Not Communicating
- Token not recognised — Badge Not Recognized / Access Denied