1300 Mitsubishi Electric — Low Pressure Alarm / Refrigerant Shortage
At a glance
- Severity
- FAULT STOP
- Domain
- HEAT_PUMP_SYSTEM
- Reference standard
- EN 378 / F-Gas EU 517/2014
- Product / context
- Low pressure fault (63L)
What it means
Low pressure in the refrigerant circuit due to insufficient charge or a leak.
Probable causes
- Refrigerant leak from fittings, flare joints or heat exchanger
- Insufficient refrigerant charge after servicing
- Filter drier clogged
- Electronic expansion valve faulty or stuck
Where to start
Are oil traces or ice visible on the refrigerant line fittings?
Full guided diagnosis in the app
The diagnostic tree for this fault has 5 guided steps with measurements, checks and resolutions. You'll find it in HVACIQ, one of the five IndexOS apps: free, works offline.
Printable sheet + Mitsubishi Electric updates
Leave your email: get the link to the printable Mitsubishi Electric error-code sheet and a heads-up when we add new codes and guides.
Double opt-in, zero spam, one-click unsubscribe.
The same fault on other brands
More Mitsubishi Electric codes
- 4250 — Compressor Fault / Overcurrent Protection
- 5105 — Outdoor Coil Sensor Fault / Evaporator Temperature Error
- 1102 — Discharge Temperature Too High
- 1102 — Capacity unbalance between circuits
- 1300 — Low Pressure Alarm / LP Lockout
- 1302 — High Pressure Alarm / HP Lockout
- 1302 — Sub-cooling fault / abnormal sub-cooling
- 1610 — Memory error / backup battery depleted