Allarme carico acqua (lavaggio) Electrolux Professional — Water Fill Timeout / Tank Not Filling
At a glance
- Severity
- FAULT STOP
- Domain
- HYDRAULIC_DRAIN_SYSTEM
- Reference standard
- UNI EN 60335-2-58 / EN 1717 (Backflow protection)
- Product / context
- Dishwasher tank fill timeout
What it means
The dishwasher opened the water inlet solenoid valve but the float switch or level pressure switch does not detect the correct level in the tank within the maximum allowed time.
Probable causes
- Upstream water shut-off valve closed or insufficient mains pressure.
- Mesh filter on the inlet solenoid valve clogged with sediment.
- Float level switch stuck in the low position by limescale deposits.
- Inlet solenoid valve faulty with open-circuit coil.
Where to start
Check the water supply valve behind or under the machine. Is it fully open? Is there running water in the premises?
Full guided diagnosis in the app
The diagnostic tree for this fault has 7 guided steps with measurements, checks and resolutions. You'll find it in HorecaIQ, one of the five IndexOS apps: free, works offline.
Printable sheet + Electrolux Professional updates
Leave your email: get the link to the printable Electrolux Professional error-code sheet and a heads-up when we add new codes and guides.
Double opt-in, zero spam, one-click unsubscribe.
The same fault on other brands
More Electrolux Professional codes
- Allarme boiler risciacquo (lavaggio) — Heating Element Failure / Water Not Heating
- Allarme pompa scarico (lavaggio) — Drain Timeout / Water in Wash Tank
- Allarme alta pressione (abbattitore) — High Pressure (HP) Alarm / Compressor Lockout
- Allarme generatore vapore (forno) — Oven Steam Generator / Humidifier Fault
- Allarme sonda cella (abbattitore) — Temperature Probe Fault / Sensor Open Circuit