039 Sungrow — Low Insulation Resistance (Riso Low)

At a glance

Severity
FAULT STOP
Domain
DC_SIDE
Reference standard
IEC 62446-1
Product / context
Low System Insulation Resistance

What it means

The inverter detects an insulation resistance to ground on the DC side below the safety threshold (e.g. < 1 MΩ).

Probable causes

Reference values

pv insulation{"test":"1000 VDC (EN 62446-1)","system_minimum":"≥ 1 MΩ","healthy_string_typical":"> 40 MΩ","nota":"Measure per polarity and per string, inverter disconnected."}

Where to start

Turn off the inverter (AC side) and open all DC disconnectors. Is the fault still displayed?