W#16#38AA Siemens — CPU ↔ I/O module communication error (backplane bus)

At a glance

Severity
FAULT STOP
Domain
PLC
Reference standard
IEC 61131-2
Product / context
Module not accessible — S7-1500 backplane bus

What it means

The CPU cannot communicate with one or more I/O modules on the backplane bus (local rack). The module appears as unreachable in the hardware configuration. Variables associated with the module are forced to zero or show substitute values.

Probable causes

Where to start

Identify the faulted module from the online diagnostics. Is the BF (Bus Fault) or SF (System Fault) LED on the module solid red?