Low Insulation Resistance Huawei — Ground Fault (GFDI / IMD)

At a glance

Severity
FAULT STOP
Domain
INVERTER_FV
Reference standard
IEC 62109-2 / IEC 61557-8 / CEI 64-8
Product / context
Low insulation resistance

What it means

The inverter detects a ground insulation fault on the DC side via the integrated Insulation Monitoring Device (IMD). The inverter shuts down for protection against electrocution and fire risk. Leakage current to ground exceeds the threshold (typically 300 mA).

Probable causes

Where to start

Turn off the inverter from the AC side (circuit breaker). Open the inverter DC disconnector. Wait 5 minutes for capacitor discharge. Disconnect all strings from the DC inputs of the inverter. Does the fault persist on the display?