Costa sensibile attiva BFT — Safety Edge / Contact Strip Fault
At a glance
- Severity
- FAULT STOP
- Domain
- GATE_GARAGE_AUTOMATION
- Reference standard
- EN 12453 / EN 12978
- Product / context
- Reversal or stop triggered by safety edge
What it means
The safety edge is in alarm or faulty: the gate will not close or reverses immediately. A deformed or compressed-stuck edge, a crushed or interrupted cable, or a wireless edge transmitter with a flat battery are the first checks.
Probable causes
- Safety edge deformed or damaged
- Safety edge cable interrupted or crushed
- Wireless safety edge transmitter module battery low
- Mechanical safety edge stuck in compressed position
Where to start
On which type of installation does the error appear?
Full guided diagnosis in the app
The diagnostic tree for this fault has 9 guided steps with measurements, checks and resolutions. You'll find it in BASIQ, one of the five IndexOS apps: free, works offline.
Printable sheet + BFT updates
Leave your email: get the link to the printable BFT error-code sheet and a heads-up when we add new codes and guides.
Double opt-in, zero spam, one-click unsubscribe.
The same fault on other brands
More BFT codes
- Errore finecorsa — Limit Switch Fault / End of Travel Error
- Fotocellule attive — Photocell Obstruction
- Protezione termica intervenuta — Gate Motor Overload
- Radiocomando non memorizzato — Radio Interference / Remote Control Failure