Allarme alta pressione Irinox — High Pressure (HP) Alarm / Compressor Lockout
At a glance
- Severity
- FAULT STOP
- Domain
- REFRIGERATION_SYSTEM
- Reference standard
- EN 378 / F-Gas Regulation
- Product / context
- High pressure switch trip
What it means
The high-pressure switch has cut power to the compressor because the refrigerant pressure in the condenser exceeded the critical threshold.
Probable causes
- Finned condenser coil clogged with dust, flour, or grease.
- Condenser fan motor burned out or jammed.
- Ambient temperature very high near the motor compartment.
- Refrigerant overcharge after incorrect service work.
Where to start
Remove the grille to inspect the motor compartment. What is the condition of the finned condenser coil?