Comunicazione OSDP interrotta HID — Reader Offline / Reader Not Communicating
At a glance
- Severity
- FAULT STOP
- Domain
- ACCESS_CONTROL
- Reference standard
- EN 60839-11 / CEI 79-18
- Product / context
- OSDP serial line to reader interrupted
What it means
The badge reader is not communicating with the access control controller. The reader LED may be off or blinking abnormally. No badge is read and the door remains locked.
Probable causes
- Wiegand or OSDP cable interrupted or with reversed polarity
- Power to reader absent (blown fuse or cut cable)
- Reader faulty internally (burned board)
- Excessive distance between reader and controller (Wiegand max 150m, OSDP max 1200m)
- Loose connector on the controller terminal strip
Where to start
Does the reader show a status LED (even if off)?
Full guided diagnosis in the app
The diagnostic tree for this fault has 7 guided steps with measurements, checks and resolutions. You'll find it in BASIQ, one of the five IndexOS apps: free, works offline.