407 GoodWe — AC Overcurrent / Overload

At a glance

Severity
FAULT STOP
Domain
INVERTER_FV
Reference standard
IEC 62109-2 / CEI 0-21
Product / context
AC Output Overcurrent

What it means

The inverter detects an AC output current exceeding the rated value. The overcurrent protection trips and the inverter shuts down. Possible damage to power components if the condition persists.

Probable causes

Where to start

With the inverter off, measure the resistance between phases and between each phase and neutral on the AC output cable (disconnected from the inverter). Are the values consistent (no short circuit)?

Full guided diagnosis in the app

The diagnostic tree for this fault has 7 guided steps with measurements, checks and resolutions. You'll find it in ElectraIQ, one of the five IndexOS apps: free, works offline.

Download on the App Store Get it on Google Play

Open ElectraIQ