Batteria bassa Bosch — Battery Low / Battery Failure

At a glance

Severity
FAULT STOP
Domain
INTRUSION_ALARM_SYSTEM
Reference standard
EN 50131 / CEI 79-3

What it means

The intrusion panel reports a low or failed battery: without mains power the system has no autonomy left. A battery past 3-5 years of life, a power supply that no longer charges, or deep-discharge sulphation are the most frequent causes.

Probable causes

Reference values

battery 12V SLA{"full":"> 12.6 V","discharged":"< 12.0 V","float":"13.6-13.8 V","typical_life":"3-5 years at 20 °C","nota":"Replace when capacity drops below 80% (EN 50131)."}

Full guided diagnosis in the app

The diagnostic tree for this fault has 9 guided steps with measurements, checks and resolutions. You'll find it in BASIQ, one of the four IndexOS apps: free, works offline.

Download on the App Store Get it on Google Play

Open BASIQ

Printable sheet + Bosch updates

Leave your email: get the link to the printable Bosch error-code sheet and a heads-up when we add new codes and guides.

Double opt-in, zero spam, one-click unsubscribe.

The same fault on other brands